ASTEL MT-800 Instructions d'exploitation

Naviguer en ligne ou télécharger Instructions d'exploitation pour Enregistreurs vidéo numériques (DVR) ASTEL MT-800. ASTEL MT-800 Operating instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 31
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Hilomast
Telescopic Masts
OPERATING INSTRUCTIONS
PNEUMATIC MASTS
& ACCESSORIES
MKII RANGE
South Midlands Communications
Issue 3
South Midlands Communications
S.M.House, School Close,
Chandlers Ford Ind. Est.
Eastleigh, Hampshire,
England. SO53 4BY
Tel: (+44)0 23 8024 6200
Fax: (+44)0 23 8024 6206
Issue 3
Vue de la page 0
1 2 3 4 5 6 ... 30 31

Résumé du contenu

Page 1 - Hilomast

HilomastTelescopic MastsOPERATING INSTRUCTIONSPNEUMATIC MASTS& ACCESSORIESMKII RANGESouth Midlands CommunicationsIssue 3South Midlands Communicati

Page 2 - CONTENTS

9To correct this, stand the mast at a vertical position and inject some Hilomast lubricating oil, allowing it to drain down inside the tubes. Then pu

Page 3

10(1) Loosen the lower pan head screw on the stainless straps (if fitted with locking collars). Remove any sealing compound from screw holes to revea

Page 4 - GENERAL INFORMATION

11(5) Clean the tubes with a cloth and examine the tube surfaces. If there are dents or sufficient surface damage to affect the seals, then the secti

Page 5

12PTFE Slide Ring Replacement (6a) The Teflon rings should be examined for scuffing and wear. If replacement is necessary they should be fitted befo

Page 6

13NYLON KEY REPLACEMENT Tools required: 3mm Allen key and screwdriver, a fine file may also be needed. (1) For this operation, dismantle as describ

Page 7

14FITTING INSTUCTIONS Magnets (1) Grease O-ring on magnet housing. (2) Remove mast cap and insert the magnets in their housing into the top tube,

Page 8

15MAST MOUNTINGS There are several mounting arrangements available for the installation of masts. They can be mounted either internally or externall

Page 10 - DISMANTLING THE MAST

Mast A Dia B Dia C D E Min E Max F Min G H Min H Max J K M Dia NH5 NH7 NH9 89 89 89 38 38 38 1161 1586 2043 252 252 252 800 1000 1200 112

Page 11

18NH NK NL NX FM VEHICLE BEARINGS (1) Select a suitable horizontal location for the roof bearing. Maximum and minimum installation dimensions are sh

Page 12

CONTENTS Page Masts General Information………………………………………………………………………….3 Head Load and Guy Radii…………………………………………………………………..4 Safety……………………………………………………

Page 13

19NY VEHICLE BEARINGS As can be seen on the drawing below, this mounting is constructed differently from the other vehicle bearing kits before, and

Page 14 - NYLON KEY REPLACEMENT

20(1) Select a suitable horizontal location for the roof bearing. Maximum and minimum installation dimensions are shown on pages 16 and 17. Ensure th

Page 15 - FITTING INSTUCTIONS

21BASE GUY ASSEMBLY This arrangement is generally the easiest method of erecting a mast on open ground. The kit is complete with the mast fittings,

Page 16 - MAST MOUNTINGS

22 TRIPOD STAND FOR NH MASTS Fitting instructions Before the tripod stand can be used, the top bearing must be fitted to the mast as follows: (1)

Page 17

23 Erecting Instructions (1) Place the stand in position on the ground and hinge the three legs out into horizontal position. (2) Place the mast i

Page 18

24 FIELD STAND (N4L/102) FOR NK MASTS (1) Remove inlet valve with box spanner provided. (2) On the NK16 masts only, fit the first split collar app

Page 19

25COMPRESSORS GENERAL INFORMATION Hilomast compressors are air cooled, oil-less electric motors of the diaphragm type enclosed in a steel case. All

Page 20 - NY VEHICLE BEARINGS

26TYPES OF COMPRESSORS Type NC1 Single unit Output: 17 litres/minute at 0.7kg/cm² Fuses: 12VDC = 10A, direct switching 24VDC = 5A, d

Page 21

27OPERATING INSTRUCTIONS NC1 Unit (1) Connect compressor to suitable power supply. (2) Connect airline to mast inlet valve. (3) Close exhaust

Page 22 - TOP GUY ASSEMBLY

28SETTING COMPRESSOR PRESSURE Setting Pressure Switch in the Compressor Set pressure switch only when pressure is applied to the system. A gauge mu

Page 23 - TRIPOD STAND FOR NH MASTS

2IMPORTANT INFORMATION Before using the mast carefully read the operating instructions herein. DO NOT use the mast unless it is fully extended.

Page 24

29USE OF THIRD PARTY COMPRESSORS When using third party compressors, ensure that the tank pressure is set to a maximum of 25 p.s.i. To ensure proper

Page 25

South Midlands CommunicationsS.M.House, School Close,Chadlerds Ford Ind. Est.Eastleigh, Hampshire,England. SO53 4BYTel: (+44)0 23 8024 6200Fax: (+44)0

Page 26 - COMPRESSORS

3MASTS GENERAL INFORMATION Telescopic masts are considered to be temporary structures and should not be expected to withstand all weather condition

Page 27 - TYPES OF COMPRESSORS

4LOADINGS – WIND SPEEDS – GUY RADII FOR HILOMASTS Vertical headload Maximum wind speed unguyed Maximum wind speed with top guys Antenna side surface

Page 28 - OPERATING INSTRUCTIONS

5SAFETY At times be aware of overhead obstructions especially power lines (we recommend use of the Sigalarm, high voltage power line proximity warni

Page 29

6OPERATING INSTRUCTIONS NH/NK/NL/NX Series Hilomasts (1) Close the mast exhaust valve by turning in a clockwise direction until finger tight. (2

Page 30

7Note: The locking collars are adjusted during assembly. However, if any locking collar is not clamping the section securely when fully tightened, if

Page 31 - South Midlands Communications

8MAINTENANCE AND REPAIR Mast maintenance Inspect and lubricate mast sections at four-week intervals or every 200 operations, whichever occurs first